1000 rev/min. 6 Pole. Basic Design. Operating Characteristcs

Rated Output
Frame
Rated
Current A
Rated Speed rpm
Power
Factor
Efficiency

IST
/ IR

TST
/ TR

GD2/
Kgm2

KW
H.P.
0.18 0.25 71 0.77 900 0.6 54 3.3 1.8 0.0043
0.25 0.33 80 1.05 900 0.6 56 3.3 1.8 0.0058
0.37 0.5 80 1.2 905 0.66 65 3.25 1.75 0.0073
0.55 0.75 80 1.5 910 0.7 72 3.5 2.4 0.0083
0.75 1 90S 2.1 920 0.72 69 4.5 2.2 0.0187
1.1 1.5 90L 2.95 9.20 0.72 72 4.4 2.2 0.022
1.5 2 100L 3.85 930 0.7 77 4.7 2.4 0.0408
2.2 3 112M 5.25 935 0.74 79 4 2 0.0554
3.7 5 132S 8.1 940 0.78 81 4 2 0.1534
5.5 7.5 132M 12.5 950 0.75 83 4.5 2.2 0.1896
7.5 10 160M 16 960 0.78 84 6 2 0.448
11 15 160L 22.8 960 0.78 86 5.8 2 0.5738
15 20 180L 27.6 970 0.85 88 6 2.2 1.034
18.5 25 200L 35 970 0.84 88 5.6 2.2 1.561
22 30 200L 42 970 0.83 88 5.6 2.2 1.76
30 40 225M 54.5 970 .86 89 60 2.2 2.93
37 50 250M 68 970 .86 90 6.0 2.1 4.0